Power & Protection
- Power Source
- 110–240 V~ mains;
built-in Li-ion backup battery;
alternative 6 V⎓ or 12–24 V⎓ PSU (sold separately) - Mains Voltage
- 110–240 V~, 50/60 Hz
Overview
- Alarm Device Type
- Control panel (hub)
- Wireless Protocol
- Jeweller, Wings
- Radio Frequency
- 866.0–866.5 MHz;
868.0–868.6 MHz;
868.7–869.2 MHz;
905.0–926.5 MHz;
915.85–926.5 MHz;
921.0–922.0 MHz - Wireless Range
- 2000 m (6561.7 ft)
System Capacity
- Max Users
- 50
- Ethernet
- 1 × 8P8C, up to 100 Mbps
- Cellular (SIM)
- 2 × micro-SIM;
2G GSM900/DCS1800 (B3/B8) - Event Log
- up to 1000 events (non-volatile onboard flash memory)
Battery
- Battery
- Built-in rechargeable Li-ion 2 Ah
- Battery Life
- up to 15 hours of offline operation (Ethernet disconnected)
Capacity
- Ajax devices
- up to 100
- Automation scenarios
- up to 32
- Security groups
- up to 9
- Rooms
- up to 50
Jeweller communication technology
- Maximum effective radiated power (ERP)
- up to 20 mW
- Radio signal modulation
- GFSK
- Polling interval
- from 12 to 300 s
Communication Channels
- Cellular
- 2 micro-SIM slots
- Cellular Bands
- 2G: PCS1900/DCS1800/GSM850/GSM900 (B2/B3/B5/B8)
- Automatic switching between communication channels
- Between Ethernet and SIM — instantly.;
Between SIMs — up to 4 minutes. - Communication channels prioritization
- Ethernet;
Cellular connection - Alarm transmission system categories
- SP2, SP5, DP3
- Control panel operation method
- Pass-through
- Signaling security
- S2
- Information security
- I2
Notifications
- Notification types
- Push notifications;
SMS;
Calls - Event types
- Alarms;
Malfunctions;
Security mode change;
System events
Photo Verification
- Photo Verification Types
- Photo by alarm;
Photo by scenario;
Photo on demand;
Photo by schedule - Photo Delivery Time
- up to 9 s
- Photo Resolution
- up to 640 × 480 pixels
- Number of Photos in a Series
- from 1 to 5 pictures
Monitoring
- Supported protocols
- SIA (DC-09);
SurGard (Contact ID);
ADEMCO 685;
Other proprietary protocols - Event types
- System alarms and events;
Panic button coordinates;
Photo verification
Power Supply
- Main power supply type
- type A
- Device operating AC voltage range
- 110–240 V~, 50/60 Hz
- Device operating DC voltage range
- 3.55–4.2 V⎓
- Autonomous operation
- up to 15 hours
- Alternative
- 6 V⎓;
12–24 V⎓
Sabotage Protection
- Protection against spoofing
- device authentication;
Frequency hopping
Enclosure
- Dimensions
- 6.42″ × 6.42″ × 1.42″
- Operating Humidity
- up to 75%
- Colors
- Black;
White